Rockwell Automation Publication 1441-UM001B-EN-P - September 2012 57
Configuring the Dynamic 2500 Data Collector Chapter 2
Configure the Data Collection Options
The data collection options affect the measurement, the data collection process,
and how the data displays on the Dynamix 2500 data collector. The instrument
stores the data collection settings even when the instrument is powered off.
However, you should check these options each time you start data collection.
Follow these steps to download a Route onto the data collector using the
Emonitor software.
1. Using the Route Manager, select an appropriate route and press Enter.
Transducer Change Notification of a transducer change.
If set to Warn, a prompt appears on the screen warning you of the
transducer change.
Warn (default)
Do not warn
Bias Check The bias of the transducer before taking the measurement. Manual (default)
Automatic
Module ICP The Module ICP option allows the manual control of turning off/on ICP
power to transducers in application modules.
Never
Always
Auto
Language Sets the language for the user interface. Chinese
English
Francais
Deutsch
Italiano
Portuguese (Brasil)
Russkiy
Espanol (Spain, traditional)
Table 13 - Setup Screen Parameter Descriptions
Parameter Description Value