Publication 1763-UM001E-EN-P - June 2015
214 Connecting to Networks via Ethernet Interface
The MicroLogix 1100 supports Ethernet communication via the Ethernet
communication channel 1 shown in the drawing below.
MicroLogix 1100
Performance
Considerations
Actual performance of an MicroLogix 1100 controller varies according to:
size of Ethernet messages.
frequency of Ethernet messages.
network loading.
the implementation of and performance of your processor application
program.
12
11
Channel 1
Ethernet
(10/100Base-T)
Channel 0
RS-232/485
(DH485, DF1, or ASCII)
Side View
Optimal Performance: RSLinx to MicroLogix 1100 Series A OS FRN3
controller(2-node Ethernet network)
Operation Words MSG per Second Words per Second
Single Typed Read 1 20 20
Single Typed Reads 20 20 400
Single Typed Reads 100 20 2000
Optimal Performance: MicroLogix 1100 FRN3 to MicroLogix 1100 Series A OS FRN3
controller(2-node Ethernet network)
Operation Words MSG per Second Words per Second
Single Typed Read 1 11 11
Single Typed Reads 20 11 220
Single Typed Reads 100 11 1,100

Table of Contents

Other manuals for Allen-Bradley MicroLogix 1100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley MicroLogix 1100 and is the answer not in the manual?

Allen-Bradley MicroLogix 1100 Specifications

General IconGeneral
Processor32-bit
Programming SoftwareRSLogix 500
MountingDIN rail or panel mount
Power Supply24V DC
TypeCompact PLC
Digital Inputs12
Digital Outputs8
Analog Inputs4 (depending on model)
Analog OutputsOptional with expansion module
Programming LanguageLadder Logic
Operating Temperature0 to 55 °C (32 to 131 °F)
SeriesMicroLogix