Publication 1752-UM001A-EN-P - October 2006
Explicit Messages 217
Monitoring Test Output Terminals
Explicit
Message
Service Function
Command
Response
Service
Code
Class
ID
Instance
ID
Attribute
ID
Data Size
Monitor
Mode for
Terminal
Maintenance
Information
Read Reads the monitor mode
of maintenance
information for the test
output (1…4) specified
by the Instance ID.
0E hex 35B
hex
01…04
hex
83 hex
—
1 byte
00 hex: Total On
Time mode
01 hex: Contact
Operation Counter
mode
Write Writes the monitor mode
of maintenance
information for the test
output (1…4) specified
by the Instance ID.
10 hex 35B
hex
01…04
hex
83 hex 1 byte
00 hex: Total On
Time mode
01 hex: Contact
Operation
Counter mode
—
SV for Test
Output Total
On Time or
Contact
Operation
Counter
Read Reads the SV of the total
on time or contact
operation counter for the
input (1…4) specified by
the Instance ID.
0E hex 35B
hex
01…04
hex
86 hex
—
4 bytes
0000 0000 to
FFFF FFFF hex
(0 to 4,294,967,295)
Write Writes the SV of the total
on time or contact
operation counter for the
input (1…4) specified by
the Instance ID.
10 hex 35B
hex
01…04
hex
86 hex 4 bytes
0000 0000…
FFFF FFFF hex
(0…
4,294,967,295)
—
Read Test
Output Total
On Time or
Contact
Operation
Counter
Read Reads the total on time
or contact operation
counter for the input
(1…4) specified by the
Instance ID.
0E hex 35B
hex
01…04
hex
84 hex
—
4 bytes
0000 0000…
FFFF FFFF hex
(0… 4,294,967,295)
Reset Test
Output Total
On Time or
Contact
Operation
Counter
Reset Resets to 0 the total on
time or contact operation
counter for the test
output (1…4) specified
by the Instance ID.
05 hex 35B
hex
01…04
hex
84 hex
——