110 Rockwell Automation Publication 1560F-UM001A-EN-P - June 2019
Chapter 4 Programming
Table 20 - Setup File Group
Setup File Group Parameters
Basic (BA) Starting (BA) Stopping (BA)
Dual Ramp
(BA)
Advanced I/O (BA) Advanced Tuning
Motor Config Input 2 Starting Mode Stop Mode Starting Mode 2 Pump Pedestal (A) Input 1 Force Tuning (A) Phase Shift 0% (A)
Line Voltage Aux 1 Config Ramp Time Stop Time Ramp Time 2 UTS Level (A) Input 2 Starter R Phase Shift 10% (A)
Starting
Mode
Aux 2 Config Cur Limit Level Backspin Timer Cur Limit Level 2 Stall Position (A) Aux 1 Config Total R Phase Shift 20% (A)
Overload
Class
Initial Torque
Initial Torque 2 Stall Level (A) Aux 1 Invert Coupling Factor Phase Shift 30% (A)
Ramp Time Starting Torque Starting Torque 2 V Shut Off Level (A) Aux 1 On Delay Inductance Phase Shift 40% (A)
Initial Torque Service
Factor
Max Torque
Max Torque 2 I Shut Off Level (A) Aux 1 Off Delay Speed PGain (A) Phase Shift 50% (A)
Max Torque Kickstart Time Kickstart Time 2 Notch Maximum (A) Aux 2 Config Transient Gain
(A)
Phase Shift 60% (A)
Cur Limit
Level
Motor FLC Kickstart Level Kickstart Level 2 Timed Start (A) Aux 2 Invert Phase Shift 70% (A)
Starting
Torque
Start Delay
Bypass Delay (A) Aux 2 On Delay Transient Zero
(A)
Phase Shift 80% (A)
Stop Mode Demand Period (BA) Aux 2 Off Delay Phase Shift 90% (A)
Stop Time Max Torque Num of Periods (BA) Aux Control Transient Mag
(A)
Phase Shift 100% (A)
Input 1 Rated Torque
Rated Speed Ping Degree (A)
Pings (A)
Table 21 - Motor Protection Group
Motor Protection File Group Parameters
Overload (BA) Underload (BA)
Undervoltage
(BA)
Overvoltage (BA) Jam (BA) Stall (BA) Real Power (BA)
Reactive +
Power (BA)
Motor Fault Enable Motor Fault Enable Starter Fault Enable Starter Fault Enable Motor Fault Enable Motor Fault Enable Motor Fault Enable Motor Fault Enable
Motor Alarm
Enable
Motor Alarm
Enable
Starter Alarm
Enable
Starter Alarm
Enable
Motor Alarm
Enable
Motor Alarm
Enable
Motor Alarm
Enable
Motor Alarm
Enable
Motor Restart
Enable
Motor Restart
Enable
Starter Restart
Enable
Starter Restart
Enable
Motor Restart
Enable
Motor Restart
Enable
Motor Restart
Enable
Motor Restart
Enable
Overload Class Underload F Level Jam F Level Stall Delay MWatts Ov F Level +MVAR Ov F Level
Overload Class 2 Underload F Delay Undervolt F Level Overvolt F Level Jam F Delay
MWatts Ov F Delay +MVAR Ov F Delay
Service Factor Underload A Level Undervolt F Delay Overvolt F Delay Jam A Level MWatts Ov A Level +MVAR Ov A Level
Motor FLC Underload A Delay Undervolt A Level Overvolt A Level Jam A Delay
MWatts Ov A Delay +MVAR Ov A Delay
OL Reset Level Undervolt A Delay Overvolt A Delay MWatts Un F Level +MVAR Un F Level
OL Shunt Time MWatts Un F Delay +MVAR Un F Delay
OL Inhibit Time
MWatts Un A Level +MVAR Un A Level
Overload A Lvel MWatts Un A Delay +MVAR Un A Delay

Table of Contents

Other manuals for Allen-Bradley SMC-50

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley SMC-50 and is the answer not in the manual?

Allen-Bradley SMC-50 Specifications

General IconGeneral
BrandAllen-Bradley
ModelSMC-50
CategoryController
LanguageEnglish

Related product manuals