15
We reserve the right to make technical changes.
83052300eUK © ait-deutschland GmbH
NOTICE
Dowels and screws for fastening the external
sensor are not included in the scope of supply.
Loosen cable gland from the housing of the external
sensor, lead the 2-wire cable (Ø ≤ 1.5 mm² per wire,
cable length ≤ 50 m) through the cable gland into the
housing…
Clamp on cable, tighten cable gland and close the hous-
ing of the external sensor.
hot Water sensor
The domestic hot water sensor is an optional accessory and
only functionally-relevant for a separate domestic hot water
tank. You may only use domestic hot water sensors which
have been approved by the manufacturer of the heat pump.
ATTENTION
The domestic hot water tank must be lled before
connecting the domestic hot water sensor to the
heating and heat pump regulator.
If not already prepared at the factory, mount the domestic
hot water sensor (Ø = 6 mm) on the halfway level of the
domestic hot water tank – and always above the internal
heat exchanger of the domestic hot water tank.
1 Hot-water tank
2 Domestic hot water sensor (Ø = 6 mm)
3 Heat exchanger
4 Cold water connection
5 Domestic hot water connection
external return floW sensor
The return ow sensor (optional accessory) is function-
ally-relevant for hydraulic integration of an isolating tank
(multifunction tank …). This has to be installed as follows:
ZUP
TRLext
HUP
1 Separation or multi-functional storage tank
2 Circulation pump in the separation storage tank
(heat pump circuit)
3 Circulation pump from the separation storage
tank (heating circuit)
4 External return sensor (Ø = 6 mm)
ZUP Charging loop, heat pump
HUP Discharging loop, heating circuit
Connect the return ow sensor coming from the isolating
tank to the circuit board of the heating and heat pump reg-
ulator.
Dismantling
DANGER!
Danger of fatal injury due to electric current!
Electrical connections may be installed only
by qualied electricians.
Before opening the unit, disconnect the
system from the power supply and secure it
from being switched back on!
removal of the buffer battery
ATTENTION
Before scrapping the heating and heat pump regu-
lator, remove the buffer battery on the main board.
You can use a screwdriver to remove the battery
from its bracket. Dispose of battery and electronic
components in keeping with environmental consid-
erations.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik 2.0 and is the answer not in the manual?

Alpha-InnoTec Luxtronik 2.0 Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik 2.0
CategoryController
LanguageEnglish

Related product manuals