startIng screed heatIng program
NOTICE
While the screed heating program is running, -10°C
is displayed as the outdoor temperature. It is not
possible to heat water.
Scroll all the way down the “Service Screed heating“
screen. Activate and select the menu eld “SHP start”…
A conrmation prompt appears…
NOTICE
In the screed heating program, all connected heat
generators are released if necessary. However, the
following applies:
A heating system is designed for heating in general
and not for heating screed. It may therefore be nec-
essary for the screed heating phase to integrate ad-
ditional heat generators in the system.
Acknowledge conrmation prompt. Activate and
select menu eld “Yes” or select and activate the
menu eld “No”…
NOTICE
If you respond to the conrmation prompt with
“No”, the screed heating program will not start.
If you respond to the conrmation prompt with “Yes”,
the screen will change back to the menu “Service
screed heating”.
The last menu entry is now “SHP starting”, the menu
eld “Settings” assumes a dark background:
Select the menu eld “Save settings” in order to start
the screed heating program…
The display “SHP starting” changes to “SHP running”.
After starting the screed heating program, the pro-
grammed ow temperature levels are automatically
executed in succession.
The time interval set for a ow temperature level is
not necessarily the actual time which is necessary to
reach the next ow temperature level. Depending on
the heating system and power of the heat pump, it may
take varying lengths of time until the next ow temper-
ature level is reached.
If a ow temperature level is not reached on account
of too low a heating power, a corresponding error
message will appear in the screen. The error message
informs you about the ow temperature level which
has not been reached. However, the screed heating
program continues running and attempts to reach the
next ow temperature levels.
NOTICE
After expiry of a ow temperature level, the rel-
evant time interval is set to “0h”. This ensures that
the screed heating program continues after a po-
tential power failure at the start of each ow level
at which it was interrupted.
NOTICE
If the error message “Power screed heating” ap-
pears (= error number 730), this is only an indica-
tion that the screed heating program could not pro-
cess a ow temperature level in the specied time
interval. The screed heating program continues to
run nevertheless. The error message can only be ac-
knowledged if the screed heating program has n-
ished or has been manually switched off.
Return to the „Service“ menu.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Alpha-InnoTec Luxtronik 2.0 and is the answer not in the manual?

Alpha-InnoTec Luxtronik 2.0 Specifications

General IconGeneral
BrandAlpha-InnoTec
ModelLuxtronik 2.0
CategoryController
LanguageEnglish

Related product manuals