HYC50 - Operation and Installation Guide
Version 2-2
Page 36 of 102
4 HYC50 installation and commissioning
All rights reserved. Reproduction of this document, even in part, is only permitted with the approval of alpitronic Srl.
Figure 15: Recommended and mandatory minimum distances when choosing a location
The charging station does not support an optional ventilation function.
The minimum distances to obstacles in the supply and exhaust air area specified in Figure
22 must be observed.
If HYC50 is installed in a closed or even partially closed environment, it must be prevented
that the exhaust air is reintroduced into the supply air circuit. Impaired air circulation can
lead to a reduction in the performance of the charging station.
Notice
The outlet temperature of the charger's cooling air flow can reach
temperatures of up to 75 °C.