4 HYC50 installation and commissioning
All rights reserved. Reproduction of this document, even in part, is only permitted with the approval of alpitronic Srl.
Notice
Be sure to connect the PE mains connection cable to the appropriate
flexible PE cable. The flexible PE cable is provided with a cable lug and a
yellow-green marking.
The terminal for the PE connection is attached rotated by 90°. To protect the phase cables,
a protective cover is mounted over the PE connection (3x M4x8) (see Figure 31).
Notice
Tighten the screws with a torque wrench (0.7 Nm).
Figure 31: Mounting of protective cover via PE cable terminal