Sequoia Series    105 
Command Syntax  [SOURce:]PONSetup:CURRent <NRf+> 
Parameters  range set by the LIMit:CURRent, voltage mode  and voltage range 
Examples  PONS:CURR 22 
Query Syntax  PONS:CURR? 
Returned Parameters  <NR2> 
PONSetup:FREQuency 
This command sets the initial frequency of the power source at the power on. 
Command Syntax  [SOURce:]PONSetup:FREQuncy <NRf+> 
Parameters  set by the LIMit:FREQuency 
Examples  PONS:FREQ 50 
Query Syntax  PONS:FREQ? 
Returned Parameters  <NR2> 
PONSetup:NOUTput 
This command sets the configuration of the power source to one phase or three phase if this option is 
enabled. The LAST setting causes the unit to power up in the mode it was left. 
Command Syntax  [SOURce:]PONSetup:NOUTput <selection> 
Parameters  ONEPhase|THReephase|LAST 
Examples  PONS:NOUT LAST 
Query Syntax  PONS:NOUT? 
Returned Parameters  <CRD> 
PONSetup:OLOad[:MODE] 
This command determines how the power source will react to an over current condition. In const 
current mode, the output voltage is reduced to  a value that maintains  a constant  load current. In 
constant voltage mode, the output faults to an initial value if the over current condition is maintained 
beyond the protection delay period. 
Command Syntax  [SOURce:]PONSetup:OLOad[:MODE] <mode> 
Parameters  CCURrent|CVOLyage 
Examples  OLOad CCUR 
Query Syntax  PONS:OLO? 
Returned Parameters  <CRD> 
Related Commands  CURR:PROT:STAT 
PONSetup:CURRent:PROTection:DELAY  
This command is used to set the protetction delay period. 
Command Syntax  [SOURce:] PONSetup:CURRent: PROTection:DELAY 
Parameters  0.1 to 5 
Unit  Seconds 
Examples  PONSetup:CURRent:PROTection:DELAY 0.6 
Query Syntax  PONSetup:CURRent:PROTection:DELAY? 
Returned Parameters  <NR2> 
Related Commands  OUTP:PROT:STATE 
PONSetup:CURRent:PHASE