FEC Encode/DecodeFEC Encode/Decode
OH EditOH Edit
TTI measurementTTI measurement
MSIM DetectionMSIM Detection
Alarm InsertionAlarm Insertion
Error InsertionError Insertion
Frequency OffsetFrequency Offset
Payload OffsetPayload Offset
RS(255,239) described in ITU-T Rec. G709, No FEC
All OTU, ODU bytes except MFAS and BIP8
TTI, FTFL bytes with multi-frame manner
Condition for detecting TIM can be selected.
TCM measurement On/Off
Expected MSI bytes are set from Tx Data or Received Data.
1212..55..33..22 OTN StimuliOTN Stimuli
OTL
*
OOF/LOF, OOR/LOR
OTU, ODU
*
LOS, OTU-AIS, OOF/LOF, OOM/LOM, SM-TIM, SM-BIAE, SM-BDI, SM-IAE,
ODU-AIS, ODU-OCI, ODU-LCK, PM-TIM, PM-BDI, FSF, FSD, BSF, BSD,
TCMi-TIM, TCMi-BIAE, TCMi-BDI, TCMi-IAE, TCMi-LTC (i=1-6)
Multiplexed ODU
OOF/LOF, OOM/LOM, ODU-AIS, ODU-OCI, ODU-LCK, PM-TIM, PM-BDI,
FSF, FSD, BSF, BSD
Client
Client-AIS, CSF
Insertion timing
Single, Burst, Alternate, All
*: Available for both of Normal mode and Through mode
OTL
*
MFAS, LLM
OTU, ODU
*
Bitall, FAS, MFAS, SM-BIP8, SM-BEI, PM-BIP8, PM-BEI, TCMi-BIP8, TCMi-
BEI (i=1-6), Uncorrectable Error, Correctable Error
Multiplexed ODU
FAS, PM-BIP8, PM-BEI
GMP
CRC8, CRC5, Invalid JC1, Invalid JC2,Invalid JC1&JC2
GFP
cHEC, tHEC, Superblock CRC
Inserted Error bits are editable.
Client
Bit Error
Insertion timing
Single, Burst, Alternate, Rate, Rate (Random for Bitall), All
*: Available for both of Normal mode and Through mode
±200 ppm 0.1 ppm step
Movement type
AMP
Burst Insertion (Positive(+1), Positive(+2), Negative (1))
GMP
Measurement FunctionalityMeasurement Functionality