TD 92372GB
2007-06-18/ Ver. E
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
8
Software
The software in the BS3x0 can be updated by downloading new software without
disconnecting the equipment. The new software is stored in flash memory. See
7.10
Update on page 56 for information.
Connectors
• Two 8-pin RJ45 modular jacks for data and powering
• A 6-pin RJ12 modular jack for factory testing
LEDs
Status of LED1 (lower LED) Description
Steady Green Power LED
Status of LED2 (upper LED) Description
Not lit Base station operational and no traffic on the
base station.
Flashing green All 8 speech channels are in use.
Steady green Base station operational and traffic on the base
station.
Flashing amber Software is being downloaded to the base station
Steady amber Base station is OK, but not available (self-test, not
initialized,no communication with IPBL)
2.4 AC-adapter
The AC-adapter is used to power a base station locally.
Note: The maximum length of cable from adapter must not exceed 10 meters.
Versions
BSX-0013 For European countries except U.K.
BSX-0014 For U.K.
BSX-0015 For US/Canada
BSX-0016 For Australia
(different type of mains plug)
IMPORTANT: If local power supply is used for the RFPs, the EPP cable pair must not be
connected.