EasyManuals Logo

ASCOM IP-DECT Base Station User Manual

ASCOM IP-DECT Base Station
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #51 background imageLoading...
Page #51 background image
TD 92372GB
2007-06-18/ Ver. E
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
46
7.5.18 SARI
The SARI is the broadcast identity, which uniquely identifies an IP-DECT system. It is
needed to make the IP-DECT system operate. The SARI is added in the master.
1 Select Dect > SARI.
2 Enter the licence number delivered by your supplier in the SARI text field.
3 Click “OK”.
4 Reset in order to make the changes take effect, see 7.12 Reset on page 60.
7.5.19 Configure Messaging
If an IMS is to be used in the IP-DECT system, enter the IP address following the steps
below.
1 Select DECT > SMS.
2 Enter the address to the IMS in the IMS IP Address text field.
3 Click "OK".
4 Reset in order to make the changes take effect, see 7.12 Reset on page 60.
7.5.20 Configure Air Synchronization
This section only applies to the IPBS.
Mixed System
If IPBSs and IPBLs are mixed in the same coverage area, all IPBSs must be set as "Slave". It
is not necessary to configure which RFP to synchronize with, this is handled automatically.
IPBS System
The IPBSs uses the DECT interface to synchronize, one IPBS is assigned the role as "Air
Sync Master". It is not necessary to configure which IPBS to synchronize with, this is
handled automatically. For more information on air synchronization, see System
Description Ascom IP-DECT System, TD 92375GB.
Normally only one air sync master is allowed in one site. If however the site contains for
example two buildings and no base station in one building is possible to synchronize to
any base station in the other building, in this situation a air sync master may be used in
each building. But if there is air sync coverage between the buildings only one master is
allowed in one of the buildings. If two masters are configured within the same coverage
area two different sync systems will be created instead of one. This will make handover
and roaming between the systems impossible. As a consequense the air sync slaves will
loose synchronization frequently.
Configure Air Sync mode:
1 Select DECT > Air Sync.
2 Select in the Sync mode drop-down list:
Master, if this IPBS is the Air Sync Master.
Backup Master, if this IPBS is the Air Sync Backup Master.
Slave, if this IPBS is an Air Sync Slave.
3 Click "OK".

Table of Contents

Other manuals for ASCOM IP-DECT Base Station

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ASCOM IP-DECT Base Station and is the answer not in the manual?

ASCOM IP-DECT Base Station Specifications

General IconGeneral
BrandASCOM
ModelIP-DECT Base Station
CategoryCordless Telephone
LanguageEnglish

Related product manuals