TD 92372GB
2007-06-18/ Ver. E
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
34
7.1.5 Configure the NTP Settings
Since the IPBS/IPBL does not have a battery-backed real-time clock, the internal time will
be set to 0:00 hrs, 1.1.1970 in the case of a restart.
In order to get the correct time in the system, specify the IP address of a NTP time server.
The IPBS/IPBL will synchronize its internal clock to the time server at startup and at the
specified intervals. The clock is, for example, used by the handsets and log files.
Figure 35.
Figure 21. Configure NTP settings
1 Select General > NTP.
2 Enter the IP address to the NTP server.
3 Enter a time interval in the Interval (min) text field.
4 Select time zone in Time zone drop-down list. If the desired time zone is not in the
list, select “Other” and edit the String text field following the instructions in the
next step.
5 Enter the timezone string if automatically updates summer/winter is desired.
<String = StdOffset [Dst[Offset], Date/Time, Date/Time]>
Std = Time zone (for example EST for Eastern Standard Time).
Offset = time difference between the timezone and the UTC (Universal Time
Coordinator).
Dst = summertime zone (for example EDT for Eastern Daylight Time).
Second Offset = time difference between the summer time and the UTC.
Date/ Time, Date/ Time = beginning and end of summertime.
- date format = Mm.n.d (d day of n week in the m month)
- time format = hh:mm:ss in 24-hour format.
Note that a week always starts on a Sunday and the number for Sunday is 0.
Example:
North Carolina is located in the Eastern Time Zone. Eastern Standard Time (EST) is 5
hours behind UTC (StdOffset = EST-5), the Eastern Daylight Time (EDT) is 4 hours
behind UTC (DstOffset = EDT-4). Summertime for the year 2006 begins at two a
clock, on a Sunday, the first week in April (M4.1.0/2). The summertime ends at two
a clock, on a Sunday, the fifth week in October (M10.5.0/2).
<String = EST-5EDT-4,M4.1.0/2,M10.5.0/2>
6 Click “OK”.

Table of Contents

Other manuals for ASCOM IP-DECT Base Station

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ASCOM IP-DECT Base Station and is the answer not in the manual?

ASCOM IP-DECT Base Station Specifications

General IconGeneral
BrandASCOM
ModelIP-DECT Base Station
CategoryCordless Telephone
LanguageEnglish

Related product manuals