TD 92372GB
2007-06-18/ Ver. E
Installation and Operation Manual
IP-DECT Base Station & IP-DECT Gateway
56
7.9 Backup
The IPBS/IPBL configuration can be downloaded and saved on a disc or a server. This is
useful when identical configuration should be applied to several IPBS/IPBLs, for example
when configure the slaves in a system. For information on how to load a saved
configuration on the IPBS/IPBL, see
7.10 Update on page 56.
1 Select Backup > Config
2 Click "download"
3 Click "Save" in the dialogue window and browse to the place where the
configuration should be saved.
4 Click "Save"
7.10 Update
This section describes how to do the following configurations and settings.
Update Configuration
Update Firmware
Update the Boot File
Update the RFPs
7.10.1 Update Configuration
A previously saved configuration can be loaded and activated on the IPBS/IPBL. See 7.9
Backup on page 56 for information on how to save a configuration.
1 Select Update > Config.
2 Click "Browse..." and browse to the saved configuration.
3 Click "OK"
4 Reset in order to make the changes take effect, see 7.12 Reset on page 60.
7.10.2 Update Firmware
The software can be updated. Follow the steps below to update IPBS/IPBL with the
firmware. Download firmware from the IP-DECT system provider.
Note: If this operation is interrupted, the firmware in the device will be defect. If a
firmware upload is for any reason interrupted, the firmware must be uploaded again. Do
not execute a reset before the firmware upload is complete. For information on how to
load new firmware if the IPBS/IPBL is unreachable through the web GUI, see
9.1 Load
Firmware Using the Gwload Tool on page 62.
1 Select Update > Firmware.
2 Click "Browse..." and browse to the firmware file.
3 Click "OK"
4 Reset in order to make the changes take effect, see 7.12 Reset on page 60.