Do you have a question about the Autronica Autro Safe and is the answer not in the manual?
Brand | Autronica |
---|---|
Model | Autro Safe |
Category | Smoke Alarm |
Language | English |
Provides step-by-step instructions for mounting the BS-420 / BC-420.
Provides step-by-step instructions for mounting the BS-430.
Provides step-by-step instructions for mounting the BU-BV-420.
Provides instructions for mounting loop panels BV-110 and BU-110.
Provides instructions for mounting the Power Cabinet BP-405.
Provides instructions for mounting power supply units BPS-405 and BPS-410.
Discusses output classes, paralleling, and power limitations for BP-405.
Details internal connections and serial port configurations for BS-420/BC-420.
Details the AL_Com+ connection on the BSA-400 controller board.
Details the AL_Com+ connection on the BSL-310 communication module.
Describes the ribbon cable connection for the multifunction serial port.
Describes the ribbon cable connection to the terminal block.
Requirements for a two-pole disconnect device for mains wiring.
Details shielded cable requirements and terminal connections for AutroFieldBus.
Details connections to connector J2 on the Power Board BSF-400.
Describes AutroNet network topologies and cable connections.
Details 24V power connections to the BSA-400 controller board for redundant/single cabling.
Details 24V DC outputs from BSF-400 and their intended use.
Instructions for connecting mains power (AC) to the Power Cabinet BP-405.
Step-by-step instructions for physically mounting I/O modules onto a rail.
Step-by-step instructions for removing I/O modules from the rail.
Safety reminder to ensure mains power is OFF before connecting cables.
Illustrates connections using AL_Com+ for short distances (<3 meters).
Illustrates connections using AL_Com+ and AutroFieldBus for longer distances (>3 meters).
Explains dipswitch settings for configuring BN-180 as Primary or Secondary.
Lists annual service inspection steps for the entire system.
Details connections and requirements for AutroFieldBus.
Explains dipswitch S6 settings for serial communication protocols.
Explains dipswitch S7 settings for serial communication termination.
Lists fault messages, their causes, and remedies for the BSF-400 power board.
Explains battery charging process, voltage, and temperature control.
Explains configuration settings using dipswitches and rotary switches on the BSF-400.
Provides tables for dipswitch settings S5 and S6 for AutroFieldBus and Power Unit Type.
Explains protection by electronic and regular fuses for power outputs.