116-P-ASAFE-INSTALL/DGB Rev. I, 2014-04-01, Autronica Fire And Security AS
Installation Handbook
AutroSafe Interactive Fire Detection System
Release 4

Table of Contents

Other manuals for Autronica Autro Safe

Question and Answer IconNeed help?

Do you have a question about the Autronica Autro Safe and is the answer not in the manual?

Autronica Autro Safe Specifications

General IconGeneral
BrandAutronica
ModelAutro Safe
CategorySmoke Alarm
LanguageEnglish

Summary

Pre-installation

Mounting Instructions

Mounting Fire Alarm Control Panel BS-420 / Controller BC-420

Provides step-by-step instructions for mounting the BS-420 / BC-420.

Mounting the Operator Panel BS-430

Provides step-by-step instructions for mounting the BS-430.

Mounting Repeater Panel BU-BV-420

Provides step-by-step instructions for mounting the BU-BV-420.

Mounting Loop Panels (BV-110 and BU-110)

Provides instructions for mounting loop panels BV-110 and BU-110.

Mounting Power Cabinet BP-405

Provides instructions for mounting the Power Cabinet BP-405.

Mounting Power Supply Unit BPS-405 / BPS-410

Provides instructions for mounting power supply units BPS-405 and BPS-410.

Power Consumption

Power Design Considerations

Discusses output classes, paralleling, and power limitations for BP-405.

Connecting Internal Cables

BS-420 / BC-420

Details internal connections and serial port configurations for BS-420/BC-420.

AL_Com+ Connection on Controller Board BSA-400

Details the AL_Com+ connection on the BSA-400 controller board.

AL_Com+ Connection on Communication Module BSL-310

Details the AL_Com+ connection on the BSL-310 communication module.

Multifunction Serial Port Connection on Controller Board BSA-400

Describes the ribbon cable connection for the multifunction serial port.

Multifunction Serial Port Connection on Terminal Block, List L1

Describes the ribbon cable connection to the terminal block.

Connecting External Cables

Mains Wiring - Two-pole Disconnect Device

Requirements for a two-pole disconnect device for mains wiring.

Connections to BS-420/BC-420 - Terminal Block (List 1)

Details shielded cable requirements and terminal connections for AutroFieldBus.

Connections to Connector J2, Power Board BSF-400

Details connections to connector J2 on the Power Board BSF-400.

Connection of Network Cables (AutroNet)

Describes AutroNet network topologies and cable connections.

Connections to Controller Board BSA-400

Details 24V power connections to the BSA-400 controller board for redundant/single cabling.

Connections to Power Board BSF-400

Details 24V DC outputs from BSF-400 and their intended use.

Mains Power Connections

Instructions for connecting mains power (AC) to the Power Cabinet BP-405.

Installing I/O Modules

Mounting

Step-by-step instructions for physically mounting I/O modules onto a rail.

Removing

Step-by-step instructions for removing I/O modules from the rail.

Before Connecting Cables

Safety reminder to ensure mains power is OFF before connecting cables.

Dual Safety Installation

Example 1: Connections Using AL_Com+ only

Illustrates connections using AL_Com+ for short distances (<3 meters).

Example 2: Connections using both AL_Com+ and AutroFieldBus

Illustrates connections using AL_Com+ and AutroFieldBus for longer distances (>3 meters).

Switch Settings – AutroKeeper BN-180

Explains dipswitch settings for configuring BN-180 as Primary or Secondary.

Service and Maintenance

Annual Service and Maintenance

Lists annual service inspection steps for the entire system.

Appendix A - Controller Board BSA-400

AutroFieldBus Connections

Details connections and requirements for AutroFieldBus.

Multifunction Serial Port Dipswitch Settings – Switch S6 (RS-232, RS-422, RS-485)

Explains dipswitch S6 settings for serial communication protocols.

Multifunction Serial Port Dipswitch Settings – Switch S7

Explains dipswitch S7 settings for serial communication termination.

Fault messages Power Board BSF-400

Lists fault messages, their causes, and remedies for the BSF-400 power board.

Appendix B - Power Supply

Battery Charging

Explains battery charging process, voltage, and temperature control.

Configuration Settings

Explains configuration settings using dipswitches and rotary switches on the BSF-400.

Dipswitch table – S5 and S6

Provides tables for dipswitch settings S5 and S6 for AutroFieldBus and Power Unit Type.

Power outputs

Explains protection by electronic and regular fuses for power outputs.