Logging parameters
Parameter Type Default
value
Is set to
default
on reset
Description
LOG_VERBOSITY Numeric 0 Yes Specifies whether verbose logging is enabled.
Assign one of the following values:
• 0: Only Info log messages are collected.
• 1: Debug and Info log messages are collected.
Use this value to collect logs for debugging
purposes.
If the parameter value is changed, changes will be
applied after reboot.
Note:
To collect application logs, you must also
enable logging and set up the local and remote
logging level on Avaya Vantage
™
. Assign one
of the following values to the SYSLOG_LEVEL
and LOCAL_LOG_LEVEL parameters:
• Debug: To collect Debug log messages.
• Notice: To collect Info log messages.
Dialing rule parameters
Parameter
Type Default value Is set to
default on
reset
Description
ENHDIALSTAT Numeric 1 Yes Specifies whether the dialing rules are
used during certain dialing activities.
Assign one of the following values:
• 0: To disable the dialing algorithm.
• 1: To enable the dialing algorithm for all
outgoing calls.
PHNCC String Null string Yes Specifies the country code. Valid values
are from 1 to 999.
PHNIC String Null string Yes Specifies the access code that you dial to
make international calls.
The value can be of 0 to 4 characters in
length. The allowed characters are 0-9, *,
and #.
PHNLD String Null string Yes Specifies the access code that you dial to
make long distance calls.
Table continues…
Avaya Breeze
™
CSDK parameters
May 2018 Installing and Administering Avaya Vantage
™
149
Comments on this document? infodev@avaya.com