98 Cyclades ACS 5000 Installation/Administration/User Guide
6. Specify an event to trigger a notification in the Alarm Trigger field.
7. Enter or change the number in the OID Type Value field.
8. Accept the trap number option or select a new one from the Trap Number pull-down menu.
9. Enter a community in the Community field.
10. Enter the IP address of the SMTP server in the Server field.
11. Enter a message in the Body text area.
12. Click OK.
13. Click apply changes.
Expert - Administration - Time/Date
An administrator can select Expert - Administration - Time/Date to configure the time and date by
manually entering the time and date information in the screen or by configuring an NTP server.
To set the time and date manually [Expert]:
1. Select Expert - Administration - Time/Date in Expert mode. The Time/Date screen appears.
2. Select a time zone from the Timezone pull-down list.
3. Type the date and time in the fields provided.
4. Click apply changes.
To configure time and date using an NTP server [Expert]:
NOTE: NTP is disabled by default.
1. Select Expert - Administration - Time/Date in Expert mode. The Time/Date screen appears.
2. Select a time zone from the Timezone pull-down list.
3. Select Enable from the Network Time Protocol pull-down menu. The NTP Server field
appears.
4. Type the IP address of the NTP server in the NTP Server field.
5. Click OK.
6. Click apply changes.
Customized time zone configuration
An administrator can click the Ed
it Custom button on the Expert - Administration - Time/Date
screen to configure a customized time zone for daylight savings time or another time zone offset
anomaly that could occur anywhere in the world. The time zone identifier is added to the Timezone
pull-down menu on the main Time/Date screen.
To create a custom time zone option [Expert]:
1. Select Expert - Administration - Time/Date. The Time/Date screen appears.
2. Click Edit Custom. The Timezone Configuration dialog box appears.