EasyManua.ls Logo

Baer DLX - Page 103

Baer DLX
178 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
103
Internal real time clock
Basic clock rate ...................................... 32,768kHz
Calendar features .................................. Leap years, summer-/wintertime
day, month, year, hour, minute, second
Accuracy/ deviation ................................ max. 30sec./month at 25°C (10ppm)
Power failure reserve ............................. min. 7 days (GoldCap)
External radio clock (optional)
Type ...................................................... DCF77 receiver module AWS0
Manufacturer ......................................... Fa. Meinberg, Bad Pyrmont, Germany
Display ................................................... Modulation LED
Connection ............................................ to SYN control input (S0)
Internal modem (optional)
Type ...................................................... internal
L834 .................................... PSTN “LGO 834”: housing for panel mounting only
MOD .................................... PSTN “UniMod”: housing for panel mounting and
19”-rack
ISDN .................................... Digital-Modem
ETH ..................................... LAN/Ethernet-Connection
Display ................................................... LED on the front
Max. transmission rate ........................... internal: 9600Baud
external: according to access line
M-Bus interface (optional)
Standard ................................................ TC 176/N17 Part 3
Typ. M-Bus voltage ................................ 24VDC to 42VDC
Max. M-Bus voltage ............................... 50V
Idle current ............................................. < 2mA
Active current ......................................... 10 to 20mA
Baud rate ............................................... 300 to 2400 baud (with good lines up to 9600)
M-Bus length ......................................... max. 5km
Fiber-optic connection (FO; optional)
Wave length ........................................... 820nm
Cable code ............................................ 50/125
µ
m, 62,5/125
µ
m, 100/140
µ
m or 200
µ
m HCS
(Multimode)
Connection/Terminal code ..................... ST or SMA connector
Baud rate ............................................... 300 to 9600 baud
Cable length .......................................... max. 2,7km
20mA/CS interface (optional)
Standard ................................................ IEC62056-21 (IEC61107)
Max. voltage .......................................... 30V (open-circuit)
Max. current ........................................... 30mA
Baud rate ............................................... 300 to 9600 baud (fix baud rate)