RS485 interface (2 or 4 wires; optional)
Standard ................................................. ANSI/TIA/EIA-485-A-98
Voltage ................................................... 0VDC / 5VDC
Number of partner .................................. max. 32
Cable length ........................................... max 1,2km
Baud rate ................................................ 300 to 9600 baud
Termination(120
) ................................. none
Protection against voltage and other disturbances
Protective measures according to VDE 0701:
Protective earth impedance ..........
300m
Insulation measurements .............. protective class II,
2M
Earth leakage current ................... with protection capacitor
7mA
Insulation strength according to DIN 43863
Electro static discharge according to EN 61000-4-2:
Discharge with contact .................. 4kV
Discharge through air ................... 8kV
Electromagnetic HF protection according to EN 61000-4-3 and ENV 50204:
Frequency range .......................... 80MHz to 1000MHz
Severity level ................................ 3
Test field strength ......................... 10V/m
Fast transient protection according to EN 61000-4-4:
Power supply ................................ 2kV
Inputs & outputs ............................ 2kV
Serial interfaces & modem ............ 2kV
Voltage peaks according to EN 61000-4-5:
Live to Neutral .............................. 2kV
Live and Neutral to PE ................. 4kV
Asymmetric high frequency, modulated amplitudes according to EN 61000-4-6:
Severity level ................................ 3
Inject currents ............................... 0,15MHz to 80MHz; 80 % AM, 1kHz
Magnetic field with energy frequency according to EN 61000-4-8:
Severity level ................................ 4
Magnetic field strength .................. 30A/m
Supply outages, dips and variations according to EN 61000-4-11
Modulation of supply current according to EN 61000-3-2:
Threshold value ............................ acc. to class A
Voltage range according to EN 61000-3-3