9424200994 Rev N 653
Firmware
Version and Date
Change
2.07.00, Nov-13
• Made alarms available in BESTlogicPlus
• Expanded Target Reset logic point to operate from all target
reset requests
• Added an option to Modbus to perform group saves to reduce
write times
• Made Settings Group available in scrolling screens
• Added Power Loss alarm
• Eight additional 49RTD elements
• Improved 60FL coordination when upstream breakers open
• Improved tracking of failed login attempts with bad user names
• Improved reporting of breaker operate time
• Added logic nodes and made minor improvements to IEC 61850
protocol
2.08.00, Apr-14
• Added a Language Selection setting to choose language for the
front-panel display
• Added Russian language option
• Corrected accuracy of 25A voltage monitor dropout timer and
slip frequency
• Updated Time Dial range for IEC curves in the 51 element
• Improved 78V for frequency out-of-range operation
• Added output hold timer to 78V
• Improved Frequency Out-of-Range alarm to indicate when any
source is out of range instead of when all sources are out of
range
• Improved 60FL operation to prevent chance of nuisance alarm
during settings group change
• Improved 40Q operation for single-phase connections
• Improved Modbus response to reads with incorrect ID
• Changed clock priority setup to prevent user from accidentally
disabling internal real-time clock
2.08.01, May-14
• Corrected issue that prevented front-panel select and operate
switches from operating the 43 switches
• Corrected placement of data on scrolling metering screens
2.08.02, Aug-14
• Added missing characters to scrolled metering screen
• Corrected shifted HMI screen headings for Watts/vars, VA/PF,
and Dip/Swell
• Corrected unsecured access on non BESTCOMSPlus ports
• Made default state of 61850 inputs available at all times
• Improved IRIG accuracy
• Corrected the function of the Block input for Analog Input
Protection elements
• Improved display of oscillographic records for 3W and 4W
configurations
• Removed blank screen from scrolling metering when 6 metering
values are selected
• Corrected uploading of a blank CID file for 61850
Table 262. BESTCOMSPlus® Software Revision History
Software
Version and Date
Change
2.04.01, May-09
• Initial release