Alarm relay
Alarm relay signals:
Errors and Warnings
Language/Units
Language
Pressure units
Temp. units
Instruction Manual w VERTICUS 5 Compressor Units
A-43
Message relay
For the alarm relay three different operating modes can be
configured. Standard mode "only errors" is that only error
can allow the relay to drop out (Fail Safe).
In the mode "Errors and warnings flashing" the relay drops
out in the event of errors, for warnings the relay flashes in
the cycle 1 sec. on, 1 sec. off. If an error and a warning exist,
the relay is continuously dropped out (error has priority).
In the mode "Errors and warnings" the relay drops out both
in the event of a warning and also in the event of an error.
Language /Units
On this page we make the region-specific settings. The
language selection can be made without logging in. For the
selection of the pressure units is possible from level "Opera
tion".
Selection pressure units: bar, Mpa, psi (all relative) ; Tempe
rature units: °C, K, °F.