3.5 Electrical data power modules
3.5.1 Electrical data BM552X power module
BM5522-
XXX8
BM5523-
XXX8
BM5524-
XXX8
BM5525-
XXX8
Rated input power
1)
4.3 kW 6.2 kW 8.2 kW 8.2 kW
Rated input current
1)
(I
eff
) 7.8 A 11.5 A 15.2 A 15.2 A
Max. input current (I
eff
) 15.5 A 23.0 A 30.4 A 40.6 A
Rated DC link voltage
1)
(U
DC
) 540 V
DC
DC link capacitance (internal) 470 µF 705 µF
DC link discharging time
(internal DC link capacitance)
340 s
510 s
Output voltage
1)2)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
8)
0 Hz to 450 Hz
Rated output current
1)4)5)6)9)
(I
AC
) at 4 kHz
3)
7.5 A 11.0 A 15.0 A 15.0 A
Rated output current
1)4)5)6)9)
(I
AC
) at 8 kHz
3)
6.0 A 8.8 A 12.0 A 12.0 A
Output peak current
1)4)5)7)9)
(I
AC
) at 4 kHz
3)
15.0 A 22.0 A 30.0 A 40.0 A
Output peak current
1)4)5)7)9)
(I
AC
) at 8 kHz
3)
12.0 A 17.6 A 24.0 A 32.0 A
Max. peak current period
7)
60 s 1 s
Power loss referring to
power input 83 W 122 W 166 W
Power input referring to control voltage 45 W
Current of the integrated brake control Max. 0.5 A
.
1)
All rated values refer to a DC link voltage of 540 V
DC
and a control voltage of 24 V.
2)
The output voltage is a pulsed DC voltage. The operating range refers to the RMS of the fundamental wave.
U
AC
3 0 V to 3
U
DC
2
----------- 10 V


=
without overmodulation of the PWM.
3)
Switching frequency of the inverter (adjustable).
4)
RMS at an environmental temperature of 40 °C.