EasyManua.ls Logo

Baumuller b maXX 5500 - LED Display Fieldbus

Baumuller b maXX 5500
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Design and Operation
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
131
of 314
4
4.4.3 LED display fieldbus
LED EtherCAT
®
Naming on the
front plate
H31 (green) X3 Link / Act Off: No connection
On: Connection
Blinking: Data transfer
H32 (yellow) ERROR On: ERROR (receiver error Phy1/Phy2)
H41 (green) X4 Link / Act Off: No connection
On: Connection
Blinking: Data transfer
H42 (yellow) RUN Off: ERROR/INIT
500 ms on /
500 ms off: PREOPERATIONAL
200 ms on /
1 s off: SAFEOPERATIONAL
On: OPERATIONAL
Type code
BM5XXX-XX
XX-XXXX-01XX
BM5XXX-XXXX-XXXX-07XX
LED VARAN
Naming on the
front plate
H31 (green)
H41 (green)
LINK On: Connection between 2 PHYs
(physical interfaces) is established.
H32 (yellow)
H42 (yellow)
ACTIVE On: Data is received or transmitted.
Type code
BM5XXX-XXXX-XXXX-02XX
LED CANopen
®
Type code
BM5XXX-XXXX-XXXX-03XX
No function
Meaning Blinking pattern
Meaning Blinking pattern

Table of Contents