Inspection intervals - maintenance notes
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
234
of 314
9.3
9.3.1 Periodic maintenance
m Environmental condition
Check points Methods and criteria Inspection intervals
Daily Semi-
ann
u-
ally
Annu-
ally
Check environmental temperature, humidity and
vibrations.
Check whether dust, oil or drops of water appear.
Visual inspection and measurement of the e
nvironmen-
tal conditions, comparison with standard values.
O
Check whether there are hazardous objects in the
vic
inity.
Visual inspection O
m Voltage
Check points Methods and criteria Inspection intervals
Daily Semi-
an
nu-
ally
Annu-
ally
Check the voltage of the power supply system and
th
e control circuits
Measurement and comparison with standard values. O
m Mechanical parts
Check points Methods and criteria Inspection intervals
Daily Semi-
annu-
ally
Annu-
ally
Are there any abnormal noises or vibrations? Visual and audio check O
Are there any loose screws? Tighten the screws. O
Are there any bent or damaged parts? Visual inspection O
Have there been any color changes due to over-
heating?
Visual inspection O
Are there any dust or dirt deposits? Visual inspection O
m Power supply
Check points Methods and criteria Inspection intervals
Daily Semi-
ann
u-
ally
Annu-
ally
Are there any missing or loose screws? Replace the screws or, respectively
, tighten them. O
Is there any deformation, cracking, damage or
color
change on the device as a result of overheat-
ing or aging?
Visual inspection O
Are there any dust or dirt deposits? Visual inspection O