4.3
4.3 Type code
The type code has the form:
BM5XXX - XXXX[Ryy] - XXXX - XXXX - XX - XXXX.
4.3.1 Explanation type code
BM5XXX-XXXX[Ryy]-XXXX-XXXX-XX-XXXX Device generation
BM5XXX-XXXX[Ryy]-XXXX-XXXX-XX-XXXX Device design
0: Mains rectifier
1: Active mains rectifier
3: Axis unit safety
5: Basic unit/power module safety, universal units
6: Basic unit safety, acceleration units
7: Basic unit/power module safety, continuous current unit, water-cooled
BM5XXX-XXXX[Ryy]-XXXX-XXXX-XX-XXXX Housing size
1 to 7, refer to ZDimensions– from page 29.
BM5XXX-XXXX[Ryy]-XXXX-XXXX-XX-XXXX Current stages (output rated current)
2 to 8 (current value dependent on the housing size),
refer to ZElectrical data basic units– from page 61.
BM5XXX-XXXX[Ryy]-XXXX-XXXX-XX-XXXX Type of cooling
S: Air-cooled with air supply and with air outlet in the control cabinet
A: Air-cooled with air supply and with air outlet outside the control cabinet
Z: Water-cooled with water cooler in the control cabinet
F: Water-cooled with water cooler outside the control cabinet
C: Cooling via mounting wall of the control cabinet (cold plate)s
BM5XXX-XXXX[Ryy]-XXXX-XXXX-XX-XXXX Power supply system
T: Grounded TN or TT systems
I: IT systems, grounded TN or TT systems, except BM551X and BM5526
G: Grounded delta systems, IT systems, grounded TN or TT systems
R: Grounded TN or TT systems with load resistor
S: IT systems, grounded TN or TT systems with load resistor:
W: Grounded delta, IT systems, grounded TN or TT systems with load resistor