Cabling
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
258
of 314
11.1
11.1.5.1 Connecting cable for resolver
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1 Utilize the following materials:
m Cable: Li9YC 1x2x0.25-Li9Y 2x2x0,25-Li9Y C11Y 1x2x0.34GN.
m High-density D-sub connector: 26-pin, male
m Round connector: 12-pin, female (e.g. from Interconnectron)
2 Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 110: Connecting cable for resolver
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not operable and could lead to de-
fects, both in the encoder module and the encoder!