Installation
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
177
of 314
7
7.11.1.3 Connection of several devices to the DC link without using the signal bus
There are the following possibilities to connect devices.
Via X300
signal bus
Do not connect power supply bus X100:3 and brake resistor bus X100:4!
Figure 86: Connection of several devices BM5500 via signal bus
Via X100
power supply bus/
bra
ke resistor bus
Brake resistor bus X100:4
Power supply bus X100:3
Power supply bus
Brake resistor bus
Power supply bus
Brake resistor bus
Power supply bus
Brake resistor bus
Do not connect signal bus!
Figure 87: Connection of several devices BM5500 without signal bus
NOTICE!
It is forbidden to connect both the signal bus X300 and the power supply bus/brake
resistor bus X100:3/X100:4. This leads to damage of the devices!