EasyManua.ls Logo

Baumuller b maXX 5500 - 10.2 Monitoring functions

Baumuller b maXX 5500
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Monitoring functions
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
238
of 314
10.2
10.2 Monitoring functions
Monitoring function Warning/error
Warning
Error
Adjustable
threshold
Adjustable
reaction
Reaction
pulse inhibit
Mains voltage Mains undervoltage X X - - X
Mains overvoltage X X - - X
Phase monitoring Phase failure X X - - X
Mains failure X X X - X
1)
Ground fault Fault current to ground - X - - X
Overcurrent Motor overcurrent - X - - X
DC link DC link overvoltage - X - - X
DC link relative undervoltage X X - - X
Overload monitoring Peak current not possible at this
time
X - - - -
Heat sink temperature Temperature > threshold 1 X - X - -
Temperature > switch-off threshold - X - - X
Temperature of
device interior
Temperature > threshold 1 X - X - -
Temperature > switch-off threshold - X - - X
Motor temperature I
2
t threshold exceeded - X X - X
Threshold 1 exceeded
2)
X - X - -
Threshold 2 exceeded
2)
X - X - -
Sensor short-circuit and/or
temperature < -30 °C
2)
- X - - -
Sensor not connected and/or
temperature > 250 °C
2)
- X - - -
Maximum temperature exceeded
2)
- X X - X
Position controller Dynamic position deviation - X X X -
Static position deviation - X X X -
Encoder 1 Cable break - X X X -
Cable break (SIN
2
+ COS
2
) - X X X -
Excessive rotational speed - X X X
3)
1)
Pulse inhibit carried out after a set time interval
2)
Only if KTY/PT1000 sensor used
3)
Adjustable
X: Implemented
-: Not possible

Table of Contents

Related product manuals