Technical Data
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
89
of 314
3
3.4.2.2 Electrical data BM564X acceleration units
BM5641 BM5642
Rated input power
1)2)
57 KVA 65 kVA
Rated input current
1)2)
(I
eff
) 82 A 95 A
Distortion factor of the
input current
1)2)
(THD
I
) 50 % 50 %
Max. input current
2)
(I
eff
) 164 A 190 A
DC link rated voltage
1)
540 V
DC
DC link capacitance (internal) 3055 F
DC link capacitance (external), permitted Refer to ZPage 220–
DC link discharging time (internal DC link capacitance) 70 s
Waiting time between two switching-on operations None
Output voltage
1)3)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
11)
0 Hz to 450 Hz
Rated output current
1)5)6)7)13)
(I
AC
) at 4 kHz
4)
85 A 100 A
Rated output current
1)5)6)7)13)
(I
AC
) at 8 kHz
4)
64 A 75 A
Output peak current
1)5)6)8)13)
(I
AC
) at 4 kHz
4)
170 A 200 A
Output peak current
1)5)6)8)13)
(I
AC
) at 8 kHz
4)
128 A 150 A
Max. peak current period
8) 9)
1.25 s
Connected load DC link terminals
10)
Max. 60 kW / 120 kW (1 s)
Brake resistor current, permitted (Î) Max. 100 A
Brake resistor, external v 7.
4
14)
Brake resistor threshold (Û) 780 V
Brake resistor peak power 80 kW
Permitted continuous brake r
esistor power external 58 kW
Power loss referring to
power input 1350 W
Power input referring to control voltage 112 W
Power input of the fan of the device referring to 230 V
AC
9)
87 W
Current of integrated brake control Max. 8.0 A
12)
Cooling air requirement device internal space 60 m
3
/h
Requirements to water
cooling Refer to ZPage 59–