Cabling
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
260
of 314
11.1
11.1.5.3 Connecting cable for encoder with EnDat
®
or SSI
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1 Utilize the following materials:
m Cable: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m High-density D-sub connector: 26-pin, male
m Round connector: 17-pin, female (e.g. from Interconnectron)
2 Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 112: Connecting cable for encoder with EnDat
®
or SSI
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not functionally operable and could
lead to defects, both in the encoder module and the encoder!