10.4 Error handling
Error
acknowledgment
If the red error LEDs H14 light up, at least one error exists.
Error acknowledgments cause all error messages to be reset. Individual acknowledgment
of errors is not possible. An acknowledgment causes deletion of the errors if deletion was
possible on account of the error circumstances.
There are three methods of acknowledging an error:
m By means of write access to the control word
m Via a digital input
m Via the pulse enable input
This is conditional upon the drive only being controlled via the hardware inputs (thus,
the control of the motor is not handled via another communications channel). Further
-
more, the option „Error acknowledgment by means of pulse enable“ must be activated.
The errors are acknowledged with the first rising signal edge of the pulse enable. How
-
ever, the drive has still not started. A second rising signal edge is then necessary for
the release.
For further information on the subject of error acknowledgment, refer to „Parameter man-
ual b maXX 5000".
NOTE!
The device is shipped with predefined error reactions. With regard to the error mes-
sages identified with „depending on the setting“ in the „Reaction“ column, the device's
error reaction can be adjusted. Errors that, due to safety reasons, have an immediate
pulse inhibit as a consequence, may not be changed.