Installation
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
193
of 314
7
7.12 Controller terminals
Type code: BM5XXX-XXXX-XX01 bzw. XX06
Figure 97: Connections controller
X1: Service interface
NOTE!
Only the service cable BM5-K-USB-XXX is
allowed to be used for the service interface
X1, refer to ZService interface cableon
page 293
X2 Digital inputs/outputs
1:Refer to ZPage 195
2 to 3: BB On (SELV/PELV)
4 to 7: Digital output (SELV/PELV)
8: Refer to ZPage 195
9 to 10: N.C.
11: +24V (SELV/PELV)
12: M24V (SELV/PELV)
13: Fast dig. input 1 / quick stop (
SELV/PELV)
14: Fast dig. input 2 (SELV/PELV)
15 to 19: Digital input (SELV/PELV)
20: Dig. input 8 / pulse enable
1 11
10 20
BM5XXX-XXXX-XXXX-00XX
No function
BM5XXX-XXXX-XXXX-01XX
X3 EtherCAT
®
-IN X4 EtherCAT
®
-OUT
BM5XXX-XXXX-XXXX-02XX
X3 VARAN-IN X4 VARAN-OUT
1: TX+
2: TX-
3: RX+
4 to 5: Reserved
6: RX-
7 to 8: Reserved
A: Assembly opening additional module
The delivery status is: empty
The operation is only with an BM5-O-SAF-
XXX permitted / possible. (Mounting refer to
manual 5.09013 and/or 5.11016). It is not
allowed to plug any other modules in.