Design and Operation
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
133
of 314
4
4.4.4 Setting the IP address with address switches
EtherCAT
®
CoE
EtherCAT
®
SoE
BM5XXX-XXXX-XXXX-01XX
BM5XXX-XXXX-XXXX-07XX
VARAN BM5XXX-XXXX-XXXX-02XX
POWERLINK
®
BM5XXX-XXXX-XXXX-04XX
IP-Address
S1 to S4
The IP address of the controller consists of 32 bits or 4 bytes (e.g. 192.168.125.203).
Controller with EtherCAT
®
-profile: Both of the first bytes are set with the base address
(192.168.) at the factory. Both of the last bytes are set by means of the address switches
S1, S2, S3 and S4. In the process, S1 and S2 as well as S3 and S4 each represent an 8
bit value.
Controller with POWERLINK
®
-profile: Both of the first bytes are set with the base address
(192.168.100) at the factory. Both of the last bytes are set by means of the address
switches S3 and S4. In the process, S3 and S4 each represent an 8 bit value.
The IP address 192.168.0.0 or 192.168.100.0 is not permitted/reserved.
For information on changing the base address, refer to the parameter manual.
EtherCAT
®
or VARAN profile:
POWERLINK
®
profile
Switch setting up
Switch setting down
Switch setting up
Switch setting down