Design and Operation
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
129
of 314
4
4.4.1 7-segment display controller
Display
0
NOT READY TO SWITCH ON Drive message „Not ready for switching power on“
1
SWITCH-ON INHIBIT Inhibit voltage, e.g. quick stop active
2
READY TO SWITCH ON Drive shutdown
Control word: xxxx x110
Pulse enable = 0
Quick stop = 1 (low active)
3
SWITCHED ON Control word: xxxx x111
Pulse enable = 1
Quick stop = 1
4
OPERATION ENABLED Control word: xxxx 1111
Pulse enable = 1
Quick stop = 1
5
OPERATION DISABLED
ACTIVE
6
OPERATION INHIBIT ACTIVE Pulse enable = 0
7
QUICK STOP ACTIVE Quick stop = 0 (low active)
E
ERROR RESPONSE ACTIVE
F
ERROR Error message
Reset via control word 0xxx
xxxx
or reset stored errors 0
1
P
Parking axis
Refer to parameter manual for
detailed description of drive states and state transitions.
0: Low, 1: High
State
drive manager
Meaning
NOTE!
In addition the error No. is displayed, refer to ZFault detectionfrom page 243.

Table of Contents