3.5.2 Electrical data BM553X power module
BM5532-
XXX8
BM5533-
XXX8
BM5534-
XXX8
BM5535-
XXX8
Rated input power
1)
12.0 kW 15.3 kW 23.3 kW 32.3 kW
Rated input current
1)
(I
eff
) 22.3 A 28.4 A 43.2 A 59.8 A
Max. input current (I
eff
) 44.7 A 56.8 A 86.4 A 89.7 A
Rated DC link voltage
1)
(U
DC
) 540 V
DC
DC link capacitance (internal) 820 µF 1230 µF 1640 µF 2000 µF
DC link discharging time
(internal DC link capacitance)
140 s
210 s 280 s 340 s
Output voltage
1)2)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
8)
0 Hz to 450 Hz
Rated output current
1)4)5)6)9)
(I
AC
) at 4 kHz
3)
22.5 A 30.0 A 45.0 A 60.0 A
Rated output current
1)4)5)6)9)
(I
AC
) at 8 kHz
3)
18.0 A 24.0 A 36.0 A 48.0 A
Output peak current
1)4)5)7)9)
(I
AC
) at 4 kHz
3)
45.0 A 60.0 A 90.0 A 90.0 A
Output peak current
1)4)5)7)9)
(I
AC
) at 8 kHz
3)
36.0 A 48.0 A 72.0 A 72.0 A
Max. peak current period
7)
60 s
Power loss referring to the power input 250
W 318 W 490 W 685 W
Power input referring to the control voltage 58 W
Current of the integrated brake control Max. 1.0 A
1)
All rated values refer to a DC link voltage of 540 V
DC
and a control voltage of 24 V.
2)
The output voltage is a pulsed DC voltage. The operating range refers to the RMS of the fundamental wave.
U
AC
3 0 V to 3
U
DC
2
----------- 10 V


=
without overmodulation of the PWM.
3)
Switching frequency of the inverter (adjustable).
4)
RMS at an environmental temperature of 40 °C.