EasyManua.ls Logo

Baumuller b maXX 5500 - Electrical Data BM5 X2 X Universal Units

Baumuller b maXX 5500
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical data basic units
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
64
of 314
3.4
3.4.1.2 Electrical data BM5X2X universal units
BM5522 BM5523 BM5524
Rated input power
1)
5.6 kVA 8.6 kVA 11.8 kVA
Rated input current
1)
(I
eff
) 8.1 A 12.4 A 17.0 A
Total harmonic distortion input current (THD)
1)
107 % 109 % 109 %
Max. input current (I
eff
) 15.1 A 23.2 A 31.8 A
Rated DC link voltage
1)
(U
DC
) 540 V
DC
DC link capacitance (internal) 470 F 705 F
DC link discharging time (internal DC link capacitance) 340 s
510 s
DC link capacitance (external), permitted Refer to ZF
igure 36on page 66
Period between two power up processes
9)
At least 60 s
Output voltage
1)3)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
11)
0 Hz to 450 Hz
Rated output current
1)5)6)7)
(I
AC
) at 4 kHz
4)
7.5 A 11.0 A 15.0 A
Rated output current
1)5)6)7)
(I
AC
) at 8 kHz
4)
6.0 A 8.8 A 12.0 A
Output peak current
1)5)6)8)
(I
AC
) at 4 kHz
4)
15.0 A 22.0 A 30.0 A
Output peak current
1)5)6)8)
(I
AC
) at 8 kHz
4)
12.0 A 17.6 A 24.0 A
Max. peak current period
8)
60 s
Connected load DC link terminals Max. 5.0 kW
Brake resistor current, permitted (Î) Max. 9.0 A Max. 13.0 A Max. 18.0 A
Brake resistor external 86
60 44
Brake resistor threshold (Û) 780 V
Peak brake resistor power 7 kW 10 kW 14 kW
Permitted continuous brake resistor power external 3.4 kW 5 kW 6.8 kW
Power loss referring to power input 102 W 150 W 204 W
Power input referring to contr
ol voltage 45 W
Current of the integrated brake control Max. 2 A

Table of Contents