BM5525 BM5526-
XTXX
BM5527-
XTXX
Rated input power
1)
11.8 kVA 13.2 kVA
2)
16.6 kVA
2)
Rated input current
1)
(I
eff
) 17.0 A 19.0 A
2)
24.0 A
2)
Total harmonic distortion input current (THD)
1)
109 % 54 %
2)
Max. input current (I
eff
) 34.0 A 37.0 A
2)
Rated DC link voltage
1)
(U
DC
) 540 V
DC
DC link capacitance (internal) 705 F 1020 F
DC link discharging time (internal DC link capacitance) 510 s
695 s
DC link capacitance (external), permitted Refer to ZF
igure 36on page 66
Period between two power up processes
9)
at least 60 s
Output voltage
1)3)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
11)
0 Hz to 450 Hz
Rated output current
1)5)6)7)
(I
AC
) at 4 kHz
4)
15.0 A 22.5 A
12)
27.0 A
12)
Rated output current
1)5)6)7)
(I
AC
) at 8 kHz
4)
12.0 A 18.0 A
12)
21.6 A
12)
Output peak current
1)5)6)8)
(I
AC
) at 4 kHz
4)
40.0 A 45.0 A
12)
Output peak current
1)5)6)8)
(I
AC
) at 8 kHz
4)
32.0 A 36.0 A
12)
Max. peak current period
8)
1 s 8 s 25 s
Connected load DC link terminals
10)
Max. 5.0 kW
Brake resistor current, permitted (Î) Max. 25.0 A
Brake resistor external 32
Brake resistor threshold (Û) 780 V
Peak brake resistor power 20 kW
Permitted continuous brake r
esistor power external 6.8 kW
Power loss referring to
power input 204 W 300 W 350 W
Power input referring to control voltage 45 W
Current of the integrated brake control Max. 2 A
Technical Data
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
65
of 314
3
1)
All rated values refer to a DC link voltage of 540 V, a control voltage of 24 V and an environmental temperature of 40 °C.
2)
Using the power choke listed in ZPower chokesfrom page 288 at a power supply with U
K,power supply
= 0.4 %.
3)
The output voltage is a pulsed DC voltage. The operating range refers to the RMS of the fundamental wave.
U
AC
3 0 V to 3
U
DC
2
----------- 10 V


=
without overmodulation of the PWM.
4)
Switching frequency of the inverter (adjustable).
5)
RMS at an environmental temperature of 40 °C.

Table of Contents