EasyManua.ls Logo

Baumuller b maXX 5500 - Electrical Data BM557 X Power Module

Baumuller b maXX 5500
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
111
of 314
3
3.5.6 Electrical data BM557X power module
BM5572-
AXX8/FXX8
BM5573-
AXX8/FXX8
13)
Rated input power
1)
160 kW 220 kW
Rated input current
1)
(I
eff
) 300 A 410 A
Max. input current
2)
(I
eff
) 450 A 535 A
Rated DC link voltage
1)
(U
DC
) 540 V
DC
DC link capacitance (internal) 19.8 mF
DC link discharging time
(internal DC link capacitance)
150 s
Output voltage
1)2)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
11)
0 Hz to 450 Hz
Rated output current
1)4)5)6)10)
(I
AC
) at 4 kHz
3)
450 A 615 A
Rated output current
1)4)5)6)10)
(I
AC
) at 8 kHz
3)
338 A 420 A
Output peak current
1)4)5)7)12) (
I
AC
) at 4 kHz
3)
585 A 800 A
Output peak current
1)4)5)7)12)
(I
AC
) at 8 kHz
3)
439 A 545 A
Max. peak current period
7)
60 s
Power loss referring to the power input 4700 W 6450 W
Power loss referring to th
e control voltage 116 W
Power loss of the device fan
referring to 230 V
AC
8)
Max. 540 W
Current of the integrated brake control Max. 8,0 A
9)
Cooling air requirement power heatsinks 1000 m
3
/h
Cooling air requirement device internal space 250 m
3
/h
1)
All rated values refer to a DC link voltage of 540 V, a control voltage of 24 V and an environmental temperature of 40 °C.
2)
The output voltage is a pulsed DC voltage. The operating range refers to the RMS of the fundamental wave.
U
AC
3 0 V to 3
U
DC
2
----------- 10 V


=
without overmodulation of the PWM.
3)
Switching frequency of the inverter (adjustable).
4)
RMS at an environmental temperature of 40 °C.