EasyManua.ls Logo

Baumuller b maXX 5500 - Electrical Data BM553 X Universal Units

Baumuller b maXX 5500
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical data basic units
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
68
of 314
3.4
3.4.1.3 Electrical data BM553X universal units
m Without charging resistor BM553X-XT/BM553X-XG/BM553X-XI
BM5532 BM5533 BM5534 BM5535
Rated input power
1)2)
13.3 kVA 16.8 kVA 26.3 kVA 36.7 kVA
Rated input current
1)2)
(I
eff
) 19.2 A 24.2 A 38.0 A 53.0 A
Total harmonic distortion input current (THD
I
)
1)2)
60 % 54 % 57 % 57 %
Max. input current
2)
(I
eff
) 37.0 A 45.0 A 71.0 A 71.0 A
Rated DC link voltage
1)
(U
DC
) 540 V
DC
DC link capacitance (internal) 940 F 1230 F 1640 F 2000 F
DC link discharging time (internal DC link capacitance) 140 s 210 s 280 s 340 s
DC link capacitance (external), permitted Max. 20 mF
Waiting period between two switching-on operations None
Output voltage
1)3)
(U
AC
) 3 x 0 V to 3 x 370 V
Output frequency at 4 kHz
10)
0 Hz to 450 Hz
Rated output current
1)5)6)7)12)
(I
AC
) at 4 kHz
4)
22.5 A 30.0 A 45.0 A 60.0 A
Rated output current
1)5)6)7)12)
(I
AC
) at 8 kHz
4)
18.0 A 24.0 A 36.0 A
48.0 A
Output peak current
1)5)6)8)12)
(I
AC
) at 4 kHz
4)
45.0 A 60.0 A 90.0 A
90.0 A
Output peak current
1)5)6)8)12)
(I
AC
) at 8 kHz
4)
36.0 A 48.0 A 72.0 A
72.0 A
Max. peak current period
8)
60 s
Power supply DC link terminals
9)
Max. 10.0 kW
Brake resistor current, permitted (Î) Max. 36.0 A Max. 50.0 A
Brake resistor, external 22
16
Brake resistor threshold (Û) 780 V
Brake resistor peak power 29 kW 40 kW
Permitted continuous brake resistor power external 10 kW
Power loss referring to power input 300 W 390 W 600 W 840 W
Power input referring to contr
ol voltage 58 W
Current of the integrated brake control Max. 1.0 A Max. 8.0 A
11)

Table of Contents