Electrical data basic units
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
66
of 314
3.4
6)
At rated input supply voltage the device supplies the rated- / maximum output currents. At input voltages above the rated supply voltage
the output currents at constant output power have to be reduced, accordingly.
Output current [%]
Derating of the output current
BM5522 ... BM5527
Power voltage [V]
Figure 35: Derating the output current BM552X universal units
7)
The input current must be reduced between 40 °C and 55 °C, refer to correction factors at changed operating conditions ZEnvironmen-
tal temperatureon page
55.
8)
The possible overload time at this moment is dependent of the device load and the heat sink temperature. The device load is determined
by the overload monitoring of the device.
9)
The specified value is only valid if there is no additional DC link capacitance connected to the DC link terminals. Refer to ZPower on
switching frequency / DC link chargingo
n page 219 and ZFigure 36on page 66.
external DC link capacitance [µF]
0
1000
2000
3000
4000
5000
6000
7000
200 250 300 350 400 450 500
BM 4424, 4425, 4426
BM 4422, 4423
BM 4426-XTX-XXX85
BM5524, BM5525, BM5526
BM5522, BM5523
BM5526-XTX-XXX85
Maximum power supply voltage [V]
Figure 36: Maximum external DC link capacitance BM552X un
iversal units
10)
The sum of the transferred mean effective power via the DC link terminals and the transferred mean effective power via the motor ter-
minals may not exceed the specified va
lue continuously.