5 Connect the device via the power supply terminals 1U1, 1V1 and 1W1 to the power
choke output - not necessary for power modules.
6 Co
nnect the protective conductor to the terminal PE (a fixed ground conductor con-
nection is mandatorily specified).
7 Co
nnect 24 V power supply:
Terminals X100-1/2, X100-5/6
(if UL 508C is being considered, then limit the current to 4 A).
8 Co
nnect encoder (refer to ZController terminals– from page 193)
9 Connect the temperature sensor of the motor. (Observe the proper polarity!)
10 Con
nect the signal generator for the pulse enable:
via terminals X2 -20 (IF1), X2 -12 (M24V)
11 Con
nect the signal generator for the quick stop:
via terminals X2 -13 (SH1), X2 -12 (M24V)
12 De
pends on the application - not necessary for power modules - connect a brake
resistor (R
B
) via terminals Ba+, Ba-.
13 Co
nnect the motor brake (option):
Terminals X101-1/2 and X101-3/4
NOTE!
Plugging in and pulling out encoder cables while they are energized is prohibited, and
could lead to their destruction.
Therefore, always first switch off the 24 V supply voltage and lock the encoder con-
nectors when operating.