Cabling
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
252
of 314
11.1
m Motor cable with HIPERFACE DSL
®
20 A
Connect cable shield with the
housing of the connector.
Cable length
(according order)
Heat shrink tubing
Pin 1
1
3
A
D
4
Connect the cable shielding
via the strain relief clamp
of the connector housing.
400 mm
Data cable shielded
DSL- blue
DSL+ white
Pin 19 DSL-
Pin 20 DSL+
B+
B-
V
W
GN/GE
U
Figure 106: Motor cable with HIPERFACE DSL
®
20 A
Cable: 4G2.5+(2x1.0)+(2x22AWG)
Shielding: copper wires, tinned
Motor side:
Circular metal connector speedtec
®
M23 8-pin
Connect outside shielding and inside shielding with the connector housing.
Device side:
Metal D-sub connector 45°, 26-pin with electronics, part No. 460219
Connect inside shielding with the connector housing.
Circular connector
speedtec
®
M23
Type of stranding Unconnected
wires
Cross section of wire
1
U 2.5 mm² / black / U
3
V 2.5 mm² / black / V
4
W 2.5 mm² / black / W
GN/GE 2.5 mm² / green-yellow
A B+ 1.0 mm² / black
B B- 1.0 mm² / black
C - 22 AWG / white
D - 22 AWG / blue
Housing - Outside shielding
Housing - Inside shielding