EasyManua.ls Logo

Baumuller b maXX 5500 - Page 255

Baumuller b maXX 5500
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Accessories and Spare Parts
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10
255
of 314
11
m Motor cable with HIPERFACE DSL
®
36 A
Connect cable shield with the
housing of the connector.
Cable length
(according order)
Heat shrink tubing
Pin 1
Connect the cable shielding
via the strain relief clamp
of the connector housing.
400 mm
Data cable shielded
DSL- blue
DSL+
Pin 19 DSL-
Pin 20 DSL+
B+
B-
V
W
GN/GE
U
white
Figure 109: Motor cable with HIPERFACE DSL
®
36 A
Cable: 4G6.0+(2x1.0)+(2x22AWG)
Shielding: copper wires, tinned
Motor side:
Circular metal connector-pin speedtec
®
M40 9-pin
Outside shielding and inside shielding must be wired separately.
Device side:
Metal D-sub connector 45°, 26-pin with electronics, part No. 460219
Connect inside shielding with the connector housing.
Circular connector
speedtec
®
M40
Type of stranding Unconnected
wires
Cross section of wire
U
 U 6 mm² / black / U
V
 V 6 mm² / black / V
W
 W 6 mm² / black / W
 GN/GE 6 mm² / green-yellow
+ B+ 1.0 mm² / black
- B- 1.0 mm² / black
H DSL+ 22 AWG / white
L DSL- 22 AWG / blue
Housing - Outside shielding
Housing - Inside shielding

Table of Contents