Power chokes
Instruction handbook b maXX BM5500, BM5600, BM5700
Document No.: 5.13008.10 Baumüller Nürnberg GmbH
290
of 314
11.4
Figure 120: Figure power choke
I
rated AC
Induc-
tance
Type code Part No.
Type -001,
connection
copper bar
Part No.
Type -002,
connection
terminal
For devices
operated with
peak current
For devices
operated with
nominal current
25 A 1.18 mH BK3-0025/0030 368377 399136 - BM5532, BM5533
40 A 0.72 mH BK3-0040/0050 368378 399137 BM5532, BM5533 BM5534
65 A 0.45 mH BK3-0065/0080 368379 399138 BM5534, BM5535 BM5535
80 A 0.36 mH BK3-0080/0100 368380 399139 - BM5543
115 A 0.26 mH BK3-0115/0140 368381 399140 BM5543, BM5544 BM5544, BM5545,
BM5552
165 A 0.18 mH BK3-0165/0200 368382 399141 BM5545, BM5552 BM5546, BM5553
195 A 0.15 mH BK3-0195/0240 368383 - BM5546, BM5553 BM5755
275 A 105 H BK3-0275/0340 368384 - BM5554 BM5554, BM5562
365 A 80 H BK3-0365/0450 368385 - BM5562,
BM5563, BM5755
BM5563, BM5566,
BM5766
450 A 65 H BK3-0450/0550 368386 - BM5566, BM5766 -
530 A 55 H BK3-0530/0650 368387 - - BM5572
615 A 48 H BK3-0615/0750 368388 - BM5572 -
750 A 39 H BK3-0750/0920 368389 - - BM5573, BM5773
920 A 32.6 H BK3-0900/1100 368390 - BM5573, BM5773 -
1020
A
28 H BK3-1020/1250 395020 - - -