T 11 Setting out of operation, storage
11.3 Setting out of op eration
Execute the setting out of operation as follows:
1. Put the device off-circuit and assure the device against unintentional restart.
2. Check the isolation from supply of all connections (earliest 10 minutes a fter switching off).
3. Demount the connections and protect the connections according to the safety instructions.
4. Document the setting out of operation.
WARNING
The following can occur, if the safety instruction is not complied with:
• serious personal injury
• death
The danger is: electricity. Electric connections, which are not in a current-free state, carry haz-
ardous voltage levels. The modules in the device (e.g. capacitors) can contain dangerous charges!
Assure, that all electric connections are current-free and are safe against re-start. Before wor k-
ing, check at the electrical connections with suitable measuring devices, that the connections
are off-circuit. Remove the connections not until the safe isolation from supply has been
checked. 10min. after interruption of supply voltage the capacitors which are used in the
device are discharged enough, that the connections can be demounted without danger. If you
have additional capacitors connected to the DC link, the discharging also can last much longer.
In this case you must determine the necessary waiting time yourself.