T 6 Installation
6.13.1 Eno der interfaes
The devices of bmaXX® BM3400 series are basically provided with 2 encoder interfaces, which are configured
at production and therewith determines the encoder type, which must be connected.
6.13.1.1 Resolver (X24, Co ding A)
Figure 6.31: Resolver input
Pin no. Assignment
1 REF -
2 REF +
3 Not assigned
4 Not assigned
5 COS +
6 Not assigned
7 SIN +
8 SIN -
9 COS -
10 Not assigned
11 Not assigned
12 Not assigned
13 Not assigned
14 Motor temperature +
15 Motor temperature -
NOTE
Resolvers are to be used only for motors with maximum ten pole pairs.