T 6 Installation
Connector Quantity Usage Type
X101 1 motor temperature COMBICON MC 1.5/2-ST-3.5
X205 1 chopper resistor, UDC link
connection
COMBICON IC 2,5/5-ST-5,08
X204 1 motor connection COMBICON IC 2,5/4-ST-5,08
X101-1, MT+
X101-2, MT-
X205-1, 1D1
X205-2, 1C1
X205-3, Ba+
X205-4, Ba-
X205-5, BaI
X204-1, 1W2
X204-2, 1V2
X204-3, 1U2
X204-4, PE
Figure 6.25: Connections at the bottom of HS1 for type key V2
NOTE
If connection X101 is used in order to connect the motor temperature cable, the screen must
be applied flat and as near as possible to the housing of the b maXX® BM3400. It is necessary
to use a cable with separate screening for the temperature sensor lines (also see «Appendix B
- Spare parts and accessories» from page 159). At an improper or missing screening you may
reckon, that there w ill be great EMC problems!
84
Instrution Manual
b maXX
®
BM3400
from 206 Doument No.: 5.07013.03
Baumueller Kamenz GmbH