Installation
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07
201
of 358
7
Ethernet cables are available (see ZAccessories Ethernet/EtherCAT
®
.– on page 305).
Name Meaning Flashing pattern
H51 (green) X5 Link / Act off: no connection
on: connection
flash: data transmission
H52 (yellow) ERROR on: ERROR
(receiver error Phy1/Phy2)
H61 (green) X6 Link / Act off: no connection
on: connection
flash: data transmission
H62 (yellow) RUN off: ERROR/INIT
500 ms on/
500 ms off: PREOPERATIONAL
200 ms on/
1 s off: SAFEOPERATIONAL
on: OPERATIONAL