Controller terminals
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07 Baumüller Nürnberg GmbH
204
of 358
7.11
1)
Example:
Number of pole pairs motor = 3
3
1
--- 3 permitted=
Number of pole pairs resolver = 1
Number of pole pairs motor = 3
3
2
--- 1 5 not permitted=
Number of pole pairs resolver = 2
2)
Requirements to the temperature sensor:
Type Additional requirements Insulation
KTY84 - SELV/PELV
NTC (MSKL) R = 1K at T
protection
, I
max
< 2mA SELV/PELV
Pin assignment Pin no. Pin assignment
D-sub socket 15-pin
1 Resolver ref -
2 Resolver ref +
3 Reserved
4 Reserved
5 Resolver COS +
6 Reserved
7 Resolver SIN +
8 Resolver SIN -
9 Resolver COS -
10 Reserved
11 Reserved
12 Reserved
13 Reserved
14 Temperature sensor +
2)
15 Temperature sensor -
2)
* do not assign