Error handling
Instruction handbook b maXX BM4400, BM4600, BM4700
Document No.: 5.12008.07 Baumüller Nürnberg GmbH
242
of 358
9.4
P0202 Error operating system
P203 Error Proprog communication
Error No. Meaning Reaction Troubleshooting
16 Boot error IS Restart b maXX
17 Software error IS
18 Time slot configuration IS
19 Time slot - time error IS Restart b maXX;
Change configuration of the time slice operation sys-
tem
20 1 = no free memory IS Restart b maXX
21 Invalid error code IS
22 invalid warning code IS
23 incorrect FPGA version IS Contact Baumüller Nürnberg GmbH
24 Two-state controller: error while writing to target
parameter
IS Ensure that the target parameter is writable in these
operating conditions and the value to write is in the
valid value range.
25 Checksum error flash system data IS The system data in the controller flash is invalid and
was replaced by default values. These default values
are written to the flash by switching off and on.
26 Power unit is not supported IS Use an appropriate power unit or contact Baumüller
Nürnberg GmbH
27 to 31 reserved, not assigned = 0
Error No. Meaning Reaction Troubleshooting
32 Timeout protocol adjustable Restart b maXX 4000
33 Protocol structure adjustable
34 Wrong module type adjustable Contact Baumüller Nürnberg GmbH
35 Too many data in the telegram adjustable
36 Not enough data in telegram adjustable
37 Invalid operand adjustable
38 Invalid memory type adjustable Test RAM
39 Invalid operand address adjustable Enter valid address
40 Value less than the minimum value adjustable Check and adjust data set
41 Value greater than the maximum value adjustable
42 Parameter is write-protected adjustable
43 Parameters in this operation state not writable adjustable Check operating condition and parameterization
44 Invalid parameter value adjustable Enter with a valid value
45 Communication error
ProDrive controller
adjustable Establish connection again or set parameter P0290 to
0.
46 to 47 reserved, not assigned = 0